Incidents & breakdowns

Every breakdown, spillage and mill stoppage — with the repeat-fault patterns behind them.

Logged this period

8

1 still needing action

Total downtime

14h 15m

Across 5 units

Repeat faults

2

Same fault, same truck

Repeat-fault patterns
Detected by grouping identical fault types per unit — these are workshop decisions, not dispatch ones.
Breakdowns per week
Fleet total against the two units driving most of the trend.
Downtime by unit
Minutes lost across all logged incidents.
Incident register
Showing 8 of 8 records.
INC-2618high
Hydraulic failure
ZAH511 · Thulani Ngcobo
Logged
27 Aug, 09:41
Downtime
190 min
Location
Ndwedwe Plateau
Status
In progress

Driver report

Tipping ram would not lift a full body at the Maidstone yard. Oil visible on the near-side chassis rail.

Suggested resolution

Second hydraulic fault on ZAH511 in 26 days, both on the near-side ram. Pattern points at a failing seal kit rather than the pump. Recommend pulling the unit for a full ram reseal and pressure test instead of another top-up, and swap ZAH524 onto the 3244 rotation for the rest of the week.